Monthly And Initial Start-Up:
Sanitize the ice storage system
Disconnect power to the dispenser and ice machine.
Remove the dispenser front cover plate in front of the ice machine and discard all remaining ice,
Mix a solution of 1 ounce of household bleach to 2 gallons of potable water, or: mix a solution of any
approved sanitizer, following the directions for mixing and applying that sanitizer.
Unscrew the sweep arm from the rotor shaft,
and pull the rotor from the hopper.
Using a clean cloth or sponge, wipe all interior
surfaces of the storage hopper with the sanitizing
solution, allow to air dry.
Wipe all surfaces of the rotor and sweep arm
with the sanitizing solution, allow to air dry.
Lift up & out and remove the upper front panel.
Twist the clear ice chute 1/3 turn and pull down to
remove.
Locate the two thumbscrews holding the upper ice
chute and remove them. Remove the upper ice chute
from the machine.
Thoroughly wipe the surfaces of the bin door and both ice
chutes with the sanitizing solution, and allow to air dry.
Place the upper ice chute back into the dispenser and secure with the thumb screws.
Place the clear ice chute back into the dispenser and replace the upper front panel.
Reassemble the rotor and sweep arm assembly and replace the dispenser cover plate.
Reconnect power to the ice machine and dispenser.