![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/5/79/5793523e-9a6d-45fb-aa6d-99c799198beb/5793523e-9a6d-45fb-aa6d-99c799198beb-bg44.png)
68 Automower from
7. Garden example - proposed installation and settings
™
Area: 0.12 acre. There are several islands.
No guide wire is necessary. The mower’s
default settings do not need to be changed.
Timer: Operating time of 7 hours per day.
Garden shape: Open.
Exit angles: One sector 90°- 270°.
Search method: Irregular.
Delay: Guide wire 7 minutes and boundary
wire 11 minutes.
Corridor width: 6.
Area: 0.25 acre. There is one small island.
No guide wire is necessary.
Timer: Operating time of 14 hours per day.
Garden shape: Normal.
Exit angles: One sector 70°-190°.
Follow loop out: Direction to the Left,
Distance 20 m (65 ft) and Proportion 25 %.
Search method: Irregular and Follow
boundary wire in.
Delay: Guide wire 7 minutes and boundary
wire 11 minutes.
Corridor width: 6.
Area: 0.37 acre. Guide wire recommended.
Timer: Operating time of 24 hours per day.
Garden shape: Complex.
Exit angles: One sector 90°-270°.
Follow loop out: Area 1; Direction Guide,
Distance 40 m (130 ft) and Proportion 20 %.
Area 2; Direction left, Distance 50 m (165 ft)
and Proportion 40 %.
Search method: Irregular, Follow guide wire
in and Follow boundary wire in.
Delay: Guide wire 4 minutes and boundary
wire 20 minutes.
Corridor width: Guide wire 2, boundary
wire 6.
Proposals for installation and settings
3012-729
3012-730
3012-724