7. GARDEN EXAMPLE
Area: 5500 m
2
. No guide wire is necessary.
Timer: Operating time of 24 hours per day.
Exit angles: 90° - 270°.
Search method: Irregular and Follow
boundary wire in.
Delay: Guide 1 2 minutes, Guide 2 2 minutes
and boundary wire 11 minutes.
Corridor width: 19
Area: 4500 m
2
. A number of islands and a
steep slope along the boundary wire. Guide
wire recommended.
Timer: Operating time of 24 hours per day.
Exit angles: 90°-270°.
Search method: Irregular and Follow guide
wire in.
Delay: Guide 1 2 minutes, Guide 2 2 minutes
and boundary wire 99 minutes. Automower
®
is never permitted to follow the boundary
wire.
Corridor width: 19.
Area: 1600 m
2
. L-shaped garden with the
charging station placed in the large open
area. No guide wire is necessary.
Timer: Operating time of 8 hours per day.
Exit angles: 90° - 270°.
Search method: Irregular and Follow
boundary wire in.
Delay: Guide 1 2 minutes, Guide 2 2 minutes
and boundary wire 11 minutes.
Corridor width: 19
Proposals for installation and settings