HUAWEI MC509 CDMA LGA Module
AT Command Interface Specification
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
The following lists all common and specific errors.
The error causes are as follows:
1: R-UIM busy
2: operation not supported
3: Check performed in the case of no check request
4: R-UIM not inserted
5: with a PUK check request
6: R-UIM failure
7: incorrect password
8: IMEI obtaining failure from the NV or invalid IMEI
10: incorrect index
11: not found of the corresponding phonebook storage item
12: unknown
13: memory full
14: text string too long
15: too long number
16: invalid character in the number
33: Non-existence of the call corresponding to CALL_X
40: operation not allowed
Command error:
41: AT command processing failure due to occupation of the modem port; All AT
commands may encounter the error.
Table 15-2 describes the mapping between the <err> value of CME ERROR and the
string.
Table 15-2 Mapping between the <err> value of CME ERROR and the string