HP 400W Power Supply
Part Number - AC 400W PSU
515739-B21
Input Voltage Range (Vrms)
100 to 240
Frequency Range (Nominal)
(Hz)
50/60
Nominal Input Voltage (Vrms)
100 120 200 208 220 230 240
Maximum Rated Output
Wattage
400 400 400 400 400 400 400
Nominal Input Current (A rms)
5.5 5.0 2.5 2.4 2.3 2.2 2.1
Max Rated Input Wattage Rating
(Watts)
510 500 480 480 480 480 480
Max. Rated VA (Volt-Amp)
520 520 500 500 500 500 500
Efficiency (%) at Max. Rated
Output Wattage
83.0 84.0 86.0 86.0 87.0 87.0 87.0
Power Factor
0.97 0.97 0.97 0.97 0.97 0.97 0.97
Leakage Current (mA)
0.75 0.75 0.85 0.90 0.95 0.95 1.00
Max. Inrush Current (A peak)
35 35 35 35 35 35 35
Max. Inrush Current duration
(mS)
20 20 20 20 20 20 20
Maximum British Thermal Unit
Rating (BTU-Hr)
1739 1705 1636 1636 1636 1636 1636
HP 400W Power Supply
Part Number - AC 400W PSU
532092-B21
Input Voltage Range (Vrms)
100 to 240
Frequency Range (Nominal)
(Hz)
50/60
Nominal Input Voltage (Vrms)
100 120 200 208 220 230 240
Maximum Rated Output
Wattage
320 320 360 360 360 360 360
Nominal Input Current (A rms)
4015
3.41 2.23 2.16 2.03 1.94 1.86
Max Rated Input Wattage Rating
(Watts)
412 406 445 445 444 443 443
Max. Rated VA (Volt-Amp)
413 407 447 447 446 446 445
Efficiency (%) at Max. Rated
Output Wattage
77.4 78.5 80.5 80.6 80.7 80.8
81
Power Factor
0.99 0.99 0.99 0.99 0.99 0.99 0.99
Leakage Current (mA)
0.75 0.75 0.85
0.9
0.95 0.95 1.00
Max. Inrush Current (A peak)
35 35 35 35 35 35 35
Max. Inrush Current duration
(mS)
20 20 20 20 20 20 20
Maximum British Thermal Unit
Rating (BTU-Hr)
1354 1334 1462 1462 1459 1456 1456
NOTE:
To review typical system power ratings use the Active Answers Power Advisor which is available via the online tool
located at URL:
www.hp.com/go/proliant-energy-efficient
or
www.hp.com/go/hppoweradvisor
.
QuickSpecs
HP ProLiant DL320 Generation 6
Power Specifications
DA - 13344 Worldwide QuickSpecs — Version 19 — 4.22.2010
Page 39