A SERVICE OF

logo

Chapter 3. Upgrading the Enterprise Virtual Array to v3.020
Figure 3.5. Command View EVA—View Events page
c.
Click Controller Event Log.
The Controller Events page displays in a new browser window.
Figure 3.6. Command View EVA—Controller Events
(Initialized system) page
d. Verify that no unexpected Critical events have occurred in the past 48 hours.
e. If Critical events have occurred in the past 48 hours, perform the steps outlined
in the corrective action codes to correct the problems. In some cases, it might be
necessary to call your HP authorized representative to fix the problem.
6. Verify that the hosts can see the Vdisks.
7. Verify that each disk group contains a minimum of eight disk drives.
hp StorageWorks Enterprise Virtual Array Updating Product
Software Instructions
35