![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/8/a7/8a772d5f-8c0a-44be-ae88-6acfdb04b703/8a772d5f-8c0a-44be-ae88-6acfdb04b703-bg9.png)
Installation Instructions
,QVWDOOWKHVKXWRȺYDOYHRQWKHQHDUHVWIUHTXHQWO\XVHGGULQNLQJZDWHUOLQH
1
SHUT OFF THE MAIN WATER SUPPLY
AND UNPLUG REFRIGERATOR
Turn on the nearest faucet (counterclockwise) long
enough to clear the line of water.
9
Drill a 1/4” hole in the water pipe (even if using a self-
piercing valve), using a sharp bit. Remove any burrs
resulting from drilling the hole in the pipe. Take care not
to allow water to drain into the drill. Failure to drill a
1/4” hole may result in reduced ice production or smaller
cubes.
DRILL THE HOLE FOR THE VALVE
3
)DVWHQWKHVKXWRȺYDOYHWRWKHFROGZDWHUSLSHZLWK
the pipe clamp.
Tighten the clamp screws until the sealing washer
begins to swell.
NOTE: Do not overtighten or you may crush the
tubing.
NOTE: Commonwealth of Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle valves
are illegal and use is not permitted in Massachusetts.
Consult with your licensed plumber.
FASTEN THE SHUTOFF VALVE
4
7
FLUSH OUT THE TUBING
Turn the main water supply on
FRXQWHUFORFNZLVHDQGÀXVKRXWWKH
tubing until the water is clear.
6KXWWKHZDWHURȺDWWKHZDWHUYDOYH
after about one quart (1 liter) of water
KDVEHHQÀXVKHGWKURXJKWKHWXELQJ
6
CONNECT THE TUBING TO THE VALVE
Place the compression nut and ferrule (sleeve) for
copper tubing onto the end of the tubing and connect
LWWRWKHVKXWRȺYDOYH
Make sure the tubing is fully inserted into the valve.
Tighten the compression nut securely.
For plastic tubing from a GE SmartConnect
™
Refrigerator Tubing kit, insert the molded end of the
WXELQJLQWRWKHVKXWRȺYDOYHDQGWLJKWHQFRPSUHVVLRQ
nut until it is hand tight, then tighten one additional
turn with a wrench. Overtightening may cause leaks.
NOTE: Commonwealth of Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle valves
are illegal and use is not permitted in Massachusetts.
Consult with your licensed plumber.
Saddle-Type
6KXWRȺ9DOYH
Compression
Nut
SmartConnect
™
Tubing
Packing Nut
Outlet Valve
Ferrule (sleeve)
5
ROUTE THE TUBING
Route the tubing between the cold water line and the
refrigerator.
Route the tubing through a hole drilled in the wall or
ÀRRUEHKLQGWKHUHIULJHUDWRURUDGMDFHQWEDVHFDELQHW
as close to the wall as possible.
NOTE:%HVXUHWKHUHLVVXȻFLHQWH[WUDWXELQJDERXW
feet [1.82 m] coiled into 2 turns of about 10” [25 cm]
diameter) to allow the refrigerator to move out from
the wall after installation.
INSTALLING THE WATER LINE (CONT.)
1
Choose a location for the valve that is easily accessible.
It is best to connect into the side
of a vertical water pipe. When it is
necessary to connect into a horizontal
water pipe, make the connection to the
top or side, rather than at the bottom,
WRDYRLGGUDZLQJRȺDQ\VHGLPHQWIURP
the water pipe.
CHOOSE THE VALVE LOCATION
2
Washer
Inlet End
Clamp
Screw
Vertical Cold
Water Pipe
Saddle-Type
6KXWRȺ9DOYH
Pipe Clamp