![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/d/8b/d8b6087d-38c3-4a0a-a36a-f3ce553da6c9/d8b6087d-38c3-4a0a-a36a-f3ce553da6c9-bg3d.png)
Programmer’s Guide, cont’d
Integration Scaling Matrix Switcher • Programmer’s Guide4-14
Command ASCII Command Response Additional description
(host to switcher) (switcher to host)
Command/response table for IP SIS commands
Command ASCII Command Response Additional description
(host to switcher) (switcher to host)
Delay times
RGB delay (Triple-Action Switching)
X
*
X20
*3# Dly
Set switching delay of the
selected input to the selected
output. Adjustable in 0.01
second steps up to 50 = 5.0
seconds. 0 = 0.0 seconds
(default), 1 = 0.1 seconds, 2 = 0.2
seconds, and so on.
Example: 1*35*3# Dly35 Set RGB delay for output 1 set to
3.5 seconds.
Read RGB delay
X
*3#
X20
Scaler settings
Output sync format
X
*
X
*6# Syn
X
0 = RGBHV (default).
1 = RGBS.
Example: 2*0*6# Syn00 RGBHV signal on output 2.
Read output sync format
X
*6#
X
Output polarity
X
*
X
*7# Pol
X
X
:Horizontal/Vertical polarity
0 = H–/V– 2 = H+/V–
1 = H–/V+ 3 = H+/V+
Example: 1*1*7# Pol01 H–/V+ polarity on output 1.
Read output sync polarity
X
*7#
X
Set ISM name (location)
Esc X30
CN Ipn•
X30
Read ISM name (location)
Esc
CN
X30
Set GMT/date
Esc X31
CT Ipt•
The date and time entered should be Greenwich Mean Time (GMT).
Read GMT/date
Esc
CT
X32
Set IP address
Esc
•
X33
CI Ipi•
The switcher sends the response,
but the host may not receive it.
Read IP address
Esc
CI
X33
Read hardware address
Esc
CH
X35
Read # of open connections
Esc
CC
X36
Set administrator password
Esc
•
X34
CA Ipa
Read administrator password
Esc
CA
X34
Set user password
Esc
•
X34
CU Ipu
Read user password
Esc
CU
X34
When the computer is connected to the switcher via the RS-232 link, the Admin and User password
fields are not masked. If a password has been inadvertently changed to an unknown value, you can
look up and, if desired, change a password in this window without knowing the current password.
Command/response table for special function SIS commands
The syntax for setting a special function is
X
*
X?
# where
X
is the value or variable
(such as 35 in the first example below),
X?
is the function number (such as “set RGB
delay” in the first example below), and # is the execute command. To view a
function’s setting, use