Installing an X330WAN Module into an Avaya P330 Switch
Avaya X330WAN User’s Guide 11
5 Follow the post-installation checks, as described in "Power On Self Test" on
page 11.
Power On Self Test
When you power up the Avaya P330 switch with a X330WAN module inserted,
both the P330 switch and the X330WAN perform a self test. This test takes about 40
seconds to complete, and includes:
• Checksum tests of boot and system areas of Flash memory
• System memory tests
• MAC address verification test
• System timer test
• CAM (Contents Addressable Memory) tests
• Console Port tests
• Internal packet forwarding tests
• Switch and expansion module ASIC (Application Specific Integrated Circuit)
tests
• Switch and expansion module ASIC memory tests
• Expansion module interface tests
• Expansion module packet forwarding tests
After you insert an X330WAN access router module into a powered P330 switch,
causing a reset, or after a power cycle of the host P330 switch, the X330W-2DS1
startup sequence is as follows:
1 Initially all LEDs light for 15 seconds and then switch off.
2 The ALM LEDs light for 15 seconds and then switch off.
3 The TST LEDs lights for 15 seconds and then switch off.
4 At this point, the ALM LED lights again if there is no line signal detected on the
E1/T1 ports. If a signal is detected on the line, the SIG LEDs light and the ALM
LEDs switch off.
The X330W-2USP startup sequence is as follows:
1 All LEDs light for 15 seconds, then switch off.
2 All LEDs remain off for 15 seconds.
3 The OPR LED lights and remains on.
Note: LED Number 51 on the Avaya P330 switch should be ON during the self-test
procedure.
The X330WAN module must be inserted completely for the P330 switch to
successfully reset.