Using the Avaya Remote Supervisor Adapter
Alerts
36 Avaya Remote Supervisor Adapter User Guide
November 2003
Figure 14: Warning and System Alerts
See Table 4, Warning alerts, on page 36 for an explanation of warning alerts.
Table 4: Warning alerts
Alphanumeric
Pager Code
Event Action
10 Redundant
power supply
failure
[default: Disabled]: Not used in the S8500 Media Server
configuration.
11 Single fan
failure
[default: Enabled]: Generates an alert if one fan fails.
12 Temperature
irregularity
[default: Enabled]: Generates an alert if any monitored
temperature readings are outside the warning threshold. The
S8500 Media Server remains in service. To view the
threshold values associated with the temperature readings,
select System Health in the navigation pane. Under
Environmentals, Temperature, click Value. A window
opens that shows the warning reset, warning, soft shutdown,
and hard shutdown thresholds for temperatures associated
with the selected component.
13 Voltage
irregularity
[default: Enabled]: Generates an alert if any monitored
voltages are outside the warning threshold values. The
S8500 Media Server remains in service. To view the voltage
operating setting, select System Health in the navigation
pane. Under Environmentals, Voltages, click Value. A
window opens that shows the warning reset, warning, soft
shutdown, and hard shutdown thresholds for voltages
associated with the selected component.