3 Installing a New G700 with an S8300: Administer Communication Manager
Installation and Upgrades for G700 with S8300 or S8700
555-234-100 — Issue 3 — May 2003
155
List Media-Gateway Screen
2. Verify that the G700 Media Gateway has registered.
The
y in the registered field signifies that the G700 Media Gateway has registered. If the G700
should become unregistered, the
y will become an n, but the IP address will remain assigned to
the G700 Media Gateway. If the G700 has never been registered, the IP Address field will be
blank.
If the G700 fails to register, two common causes might be:
- The serial number added as the identifier for the G700 is wrong. To check, log back into the
G700 gateway and type show system. Check the serial number that appears.
- There is no IP connection between the G700 and the S8300. To check, type show mgc and
then ping mgp <controller_address>.
Enable Announcements, If Necessary
1.
Only if specifically requested by the customer or your planning documents, at the SAT prompt,
type enable announcement-board <gateway_number> V9, where
<gateway_number> is the number of the G700 Media Gateway you just added and
V9 is the
virtual slot (for example,
2V9 means Media Gateway number 2, slot V9.
2. Press ENTER to enable announcements.
The system displays the message Command successfully completed.
Save Communication Manager Translations
Save translations again after all Communication Manager administration is complete.
- At the SAT prompt, type save translations.
list media-gateway
MEDIA-GATEWAY REPORT
Number Name Identifier IP Address Registered?
1 LabA 01DR07128730 135.177.49.57 y
2 Data MG2 02DR01130356 135.177.49.90 n