Audibility of
CO Alarm Only
Audibility when
CO & Smoke Alarms are
interconnected
Models Ei261ENRC & Ei261DENRC
Ei1529RC Alarm
Control Switch
• Wall mounted
• Supplied with surface box, can be
flush mounted using a standard
35mm deep electrical socket box.
• Can be fitted anywhere in the system
• For use when interconnecting Ei160RC
smoke/heat alarms with Ei260 Series
CO alarms
• Allows Alarm Test, Hush, Locate and
Mains Check functions
Ei128RBU Relay
• Internal 5 Amp relay with Volt-free '
clean' contacts
• Contacts rated to 240V AC
• Mains operated
• 10yr+ rechargeable cell back-up
• For use with Ei128COV cover to enable
remote siting
• Switchable pulse or continuous output options
• Battery back-up allows contacts to switch
even if mains power supply fails
• For use with Ei260 Series alarms only
SAB300 Strobe
• Xenon beacon
• Mains operated
• 3W Xenon tube,0.9Hz flash rate
• For connection through an Ei128RBU relay
• Available with clear ('C') or red ('R') lens
(add suffix to product code)
• Integral mounting base
GSV415SA Gas
Solenoid Valve
• Mains operated
• For connection through an Ei128RBU relay
• Closes internal valve when mains is applied
• Push button reset
• 1/2 “ internal parallel pipe thread to ISO7-1
Ei261MEN & Ei261M
Replacement Sensor Module
• Simple plug-in installation
• Doubles life cycle of the product
• 'Ei261MEN' to suit models
Ei261ENRC/Ei261DENRC/Ei261DEN/Ei261EN
• 'Ei261M' to suit models Ei261D/Ei261
Ei260 Series
CO Alarms
Ei1529RC Control
Switch
230C
AC
Main
Supply
Ei160RC
Smoke/Heat Alarm
Ei160RC
Smoke/Heat Alarm
Ei160RC
Smoke/Heat Alarm
Wiring Diagram -
Ei1529RC Alarm Control Switch
The Problem
Audibility throughout the home is a priority,as a situation could
arise where a CO alarm is installed in a downstairs kitchen,which
has a fossil fuel burning appliance within it,and the alarm signal
may not be heard in the upstairs bedrooms or indeed other rooms.
The Solution!
Use the interconnect feature on the Ei261ENRC/Ei261DENRC to
connect to your existing Ei160RC smoke/heat alarm installation.
Then, you must introduce an Ei1529RC Alarm Control Switch
to provide control over the
whole system.
The interconnect feature allows the CO alarm to trigger all
Ei160RC mains smoke/heat alarms installed and vice-versa - giving
increased audibility in either a CO or fire situation. If all alarms are
sounding, pressing ‘Locate’ on the Ei1529RC Alarm Control Switch
will silence all the alarms except the alarm sensing a CO or fire
situation.This gives control over the system and allows occupants
to select the safest action and/or escape route.
Additionally, if found to be a false alarm,simply press ‘Hush’on the
Control Switch to silence the alarm.The entire alarm system can
also be tested regularly by pressing the ‘Test’switch.