White Rodgers 50A62-820 Baby Carrier User Manual


 
5
50A62
TERMINAL
TERMINAL
TYPE
SYSTEM COMPONENT
CONNECTION
TYPICAL SYSTEM WIRING TABLE
* maximum recommended flame probe wire length is 36 inches.
W
G
R
Y
C
MV (2 terminals)
RO1
RO2
PS
PS
GND
HL
(unused terminal)
IND
IGN
GND
GND
(unused 2 terminals)
COOL
HEAT
M1
M2
FAN
LINE
XFMR
CIR N
LINE N
XFMR N
HUM
EAC (optional)
HUM N
EAC N (optional)
TR
TH
FP
captive screw
captive screw
captive screw
captive screw
captive screw
9-pin
connector
& harness
6-pin
connector
& harness
spade terminal
spade terminal
spade terminal
spade terminal
spade terminal
spade terminal
spade terminal
spade terminal
spade terminal
spade terminal
spade terminal
spade terminal
spade terminal
spade terminal
spade terminal
spade terminal
spade terminal
low voltage thermostat W terminal (or equivalent)
low voltage thermostat G terminal (or equivalent)
low voltage thermostat R terminal (or equivalent)
low voltage thermostat Y terminal (or equivalent)
2nd wire from Y terminal goes to 24 VAC HOT side of
compressor contactor coil
24 VAC COMMON side of compressor contactor coil
gas valve (both gas solenoids are connected in parallel)
rollout switch OUTPUT
rollout switch INPUT
pressure switch INPUT
pressure switch OUTPUT
MUST BE RELIABLY GROUNDED TO CHASSIS
high limit switch input
inducer HOT side
ignitor HOT side
inducer NEUTRAL side
ignitor NEUTRAL side
circulator blower COOL SPEED terminal
circulator blower HEAT SPEED terminal
unused circulator blower terminal
unused circulator blower terminal
circulator blower FAN SPEED terminal
input voltage (120 VAC) HOT side
24 VAC transformer line voltage HOT side
circulator blower NEUTRAL terminal
input voltage (120 VAC) NEUTRAL side
24 VAC transformer line voltage NEUTRAL side
humidifier HOT side
electronic air cleaner HOT side
humidifier NEUTRAL side
electronic air cleaner NEUTRAL side
24 VAC transformer (low voltage COMMON side)
24 VAC transformer (low voltage HIGH side)
flame sensor port*