Perlick NR Series Doll User Manual


 
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specications without prior notice
3
Form No. Z2285
Rev. 10.05.10
Refrigeration and Temperature Control
Self-contained units are equipped with a heavy-duty
refrigeration system that is factory set to maintain a
product storage temperature of approximately 38° F.
Adjusting the Temperature
The temperature control is inside the cabinet on the
left-hand side of the evaporator fan panel assembly.
You will need a screwdriver to turn the adjusting
screw. Make small adjustments until the desired
temperature is achieved.
Colder Temperatures:
Turn the adjusting screw clockwise (to the right)
Warmer Temperatures:
Turn the adjusting screw counterclockwise (to the
left).
Temperature Control ‘OFF’:
Turn the adjusting screw completely counter-
clockwise to the ‘O’ position until a click is noted.
The condenser fan motor turns o and on with the
compressor. The evaporator fan motor is on all the
time.
CAUTION: Cabinet temperatures lower than 34° F
will not allow for proper defrosting of the evaporator
coil. If defrosting is necessary, turn the control knob
to the OFF position until coil is defrosted.
Cleaning the Cabinet
Use a mild detergent and water to clean the inside
and outside of the cabinet. Dry thoroughly. Never
use a scouring pad or abrasive cleanser. See the
Stainless Steel care guide on pages 4 and 5 for more
information on proper care of stainless steel.
NOTE: An industrial strength, commercial cleaner
can be used to clean the outside of painted cabinets.
Cleaning the Condenser
The condenser (located behind the front grille cover)
should be inspected every 30 days and cleaned, if
necessary. Use a long handled, sti brush or vacuum
to clean the dirt from the front surface of the con-
denser. Keeping the condenser free from dust and
dirt will ensure ecient operation.
CAUTION: Do not bend the ns while brushing the
front of the condenser.
Failure to keep the condenser clean will cause a loss
in condensing unit eciency.
Specications
For complete specications, please visit our website
at www.perlick.com.
GENERAL INFORMATION – Narrow Door Back Bar Cabinets