Kettle Thermometer Calibration
313879B 7
Kettle Thermometer Calibration
To Check Kettle Thermometer Calibration:
1. Move ThermoLazer
™
to an area with no wind.
2. Turn temperature control to 400° F (204° C).
3. Agitate material for 4 to 5 minutes.
4. After control has reached steady state temperature
and burners do not cycle more than once per min-
ute, insert remote calibrated temperature probe in
material and directly adjacent kettle temperature
control probe.
5. Compare temperature of remote calibrated temper-
ature probe to thermometer.
6. If kettle thermometer is lower than the remote cali-
brated temperature probe, turn adjusting screw
counterclockwise.
7. If the kettle thermometer is higher than the remote
calibrated temperature probe, turn adjusting screw
clockwise.
Adjust Kettle Pilot Ignitor Electrode Gap
1. Loosen screw (231).
2. Rotate ignitor electrode (7) until gap of .17 to .20 in.
(.43 to .51 cm) is achieved.
3. Retighten screw (231).
RESET
ti14525a
Adjusting Screw
ti14519a
.17 to .20 in.
7