NOTE: If installing a surface-mount changing station,
see “Installation - Surface-Mount” section.
R
ecommended Blocking:
Wood double stud blocking is necessary. Contact an architect and
building official to make sure the blocking is adequate and complies
with building codes (Fig. b).
For A. D. A. compliance, top of lower double stud MUST be 27“
(68.5 cm) from the floor.
1. Slide changer into blocking area and mark mounting hole location
on blocking studs.
HINT: This may require 2 additional people to help hold changer
in position while you are marking the locations.
2. Shim changer for a snug fit.
3. Align holes in changer with marked holes and secure using the
appropriate fasteners (Fig. c).
NOTE: It is installers responsibility to provide correct fastereners
for other substrates.
4. Ensure all seven (7) fasteners are tight.
INSTALLATION - RECESSED
Fig. c
Recess
Mounting
Holes
Recess
Mounting
Holes
Recess
Mounting
Holes
6
3 1/4" (1607 mm)
Rough-in
D
ouble Stud
D
ouble Stud
Double Stud
Double Stud
3
7/8"
(98.4 mm)
1"
(
25.4 mm)
21 3/4"
(552 mm)
Rough-in
63 1/4"
(1607 mm)
For A. D. A.
Compliance
2
7”
(
68.5 cm)
TOP
VIEW
FRONT
VIEW
A. F. F
1
9.4"
(492 mm)
Fig. b
INSTALLATION - SURFACE-MOUNT
Fig. e
Surface-Mount
Holes
Surface-Mount
Holes
Fig. d
A. F. F
1
4
3
/4
(
3
7
4
.7
m
m
)
48"
(1219 mm)
on center
Top
For A. D. A.
Compliance
48 1/2”
(123 cm)
Recommended Blocking:
If the walls do not have studs on center, then additional blocking is
necessary (Fig. d).
Contact an architect or building contractor to make sure the
blocking is adequate and complies with building codes.
For A. D. A. compliance, measure up 48 1/2” (123 cm) from the
floor and mark the wall. This locates the position for the top left
attachment hole.
NOTE:
- Changer MUST be mounted to studs (Fig. e).
- This unit incorporates a finishing collar that seats behind
the changer’s outside flange. Center the collar as the unit
is being tightened against the wall (Fig. f).
Fig. f
Collar
Unit
Wall