Avent ISIS Breast Pump User Manual


 
3. Cleaning and sterilisation
Before you use your breast pump for the first time and every time before use:
Separate all parts, then wash in the dishwasher or in warm soapy water
and rinse. Do not use antibacterial or abrasive cleaners/detergents. Sterilise
in a Philips AVENT Steam Steriliser (Electronic, Electric or Microwave), or
by boiling for 5 minutes. If using a Philips AVENT Steam Steriliser, the pump
will remain sterile in the steriliser
for a minimum of 6 hours, provided
the lid is not removed.
4. Keeping your breast pump sterile
for travel
After sterilising all parts, insert the white valve (g) and
fit the diaphragm with stem (d) onto the pump body (f).
Clip the cover (a) over the funnel and Let-down Massage
Cushion (b) and screw on the sealing base (m) in place of
the Airflex Feeding Bottle (h).
5
.
Using the ISIS Manual Breast Pump
with the AVENT VIA Storage System
Simply replace the Airflex Feeding Bottle with the VIA
Cup and Adaptor. To make the pump completely stable
insert the VIA Cup into the VIA Lid/Stand.
e
f
g
a
b
d
c
h
i
j
k
m
n
l
ISIS MANUAL BREAST PUMP
Funnel cover (same as i)
Let-down Massage Cushion
Pump cover
Silicone diaphragm
and stem*
Handle
Pump body
White valve*
BOTTLE
Airflex Feeding Bottle (125ml/4oz)
Stand (same as a)
Dome cap
Extra Soft Teat, Newborn Flow (0m+)
Screw ring
Sealing base
Sealing disc
*spares included
g
b
k
a
c
d
e
h
i
l
j
m
n
f
l
2. Detailed parts guide
4 5