Philips ISIS iQ UNO Breast Pump User Manual


 
2
All you need to assemble and use ISIS iQ UNO is shown here.If any of the parts are missing,
or if you have any questions,please contact Customer Services (see back page for details).
3
Battery Pack
Only the following batteries are
compatible with the ISIS iQ UNO
Battery Pack:Duracell Ultra M3,
Duracell Plus,Energizer Ultra Plus,
Duracell Accu (NiMH),Ansmann
(NiMH).For Duracell Acc (NiMH)
& Ansmann (NiMH) use/charge in
accordance with manufacturers
guidelines.Dispose of batteries as
per manufacturers instructions.
1x Control handle
1x Silicone diaphragm
with stem
1x White valve
1x Pump body
2x Milk container
(1x 125ml/
4oz and 1x 260ml/9oz)
1x Stand (same as )
1x Let-down Massage
Cushion
1x Funnel cover
(same as )
1x Battery pack
1x Mains power lead
1x Dome cap
1x Extra Soft,Newborn
Flow Teat
(0m+)
2x Screw ring
1x Sealing base
2x Sealing disc
f
a
b
c
d
e
f
g
h
i
j
k
l
m
n
o
h
j
i
d
e
f
g
h
a
c
b
Bottle Parts
k
l
n
o
m
ISIS iQ UNO Pump Parts Guide – Detailed
ISIS iQ UNO Pump Parts Guide
Pump Parts
Power
cable
NEVER STERILISE ORIMMERSEINWATER
Mains Power Lead
20
Need Help? Contact Customer Services (see back page for details)
°
The pump must be switched off via the control button in order
to separate these parts.If the batteries go flat mid-pumping,you may
experience difficulty.Replace the batteries or connect the pump to an
electrical socket.Turn the pump on by holding down the control
button until the light flashes ORANGE and you hear the pump turn
on (this can take up to 5 seconds).When the light turns to solid
GREEN,press and hold the control button again,to turn the pump
off.The light will go out and you can now disconnect the pump from
the power supply and separate the parts (refer to ‘Disassembling ISIS
iQ UNO’ on page 5).
°
Avoid contact with antibacterial
or abrasive
detergents/cleaners
as they can damage the plastic.Combinations of detergents,
cleaning products,sterilising solution,softened water and
temperature fluctuations may,under certain circumstances,cause
the plastic to crack.If this occurs,do not use.The pump body and
breast milk containers are dishwasher safe but food colourings
may discolour them.Follow guidelines in ‘Cleaning and Sterilising
ISIS iQ UNO’ on page 6.
Lost or damaged parts
°
Use the spare parts included with your ISIS iQ UNO or contact
Philips AVENT for replacements (see back page for details).
°
Ensure the pump is correctly assembled and switched on
with the power indicator illuminated GREEN.
°
Make sure the lead between the electrical wall socket
or battery pack and the pump is correctly connected.
°
If using the battery pack,use recommended batteries and
check they are inserted correctly.
Pump not responding
Pump light
flashing RED
°
3 flashes,delay,3 flashes etc – if the pump stops working and the
power light is flashing RED the pump has detected a vacuum fault.
Disconnect the power and check the control handle and diaphragm
for obstructions or damage.
°
Continuous RED pulsing flash – Low battery warning.
You should consider replacing the batteries.
Cracking or
discolouration
of pump parts
Difficulties in separating
the control handle from
the pump body
Troubleshooting Guide
NEVER STERILISE ORIMMERSEINWATER
Light
Power socket
Control handle
Control button
– turns pump on and
off and automates
your pumping rhythm.
Control Handle
– adjusts the pumping suction,speed
and pattern so ISIS iQ can learn and
then repeat your rhythm after only 2
compressions.
9219-iQUNO_GB_A6cov.qxd 11/5/07 09:46 Page 3