Quick Installation Guide
This Quick Installation Guide can help you install the rechargeable Lynx Plus Series Control quickly and easily by providing the
basic steps for installation using the built-in defaults and the Voice Prompt Programming mode. The Voice Prompt
Programming mode allows you to quickly program the system by responding to a series of voice prompts.
FOR DOCUMENTATION AND ONLINE SUPPORT: http://www.security.honeywell.com/hsc/resources/MyWebTech
(see Lynx Plus Series Installation and Setup Guide P/N 800-03857 or higher)
WARRANTY INFORMATION
For the latest warranty information, please go to:
www.honeywell.com/security/hsc/resources/wa
1. Install the Control
1000-300-011-V0
FRONT
CASE
MOUNTING
HOOKS
LOCKING TABS
BACK
CASE
ROTATE
FRONT CASE
UPWARD
TO RELEASE
HOOKS
GSML/GSMVL
COMMUNICATIONS
PORT
GSMVL AUDIO
CABLE CONNECTOR
BATTERY
CONNECTIONS
PLCD
CONNECTOR
TELEPHONE
CONNECTION
2. Make Wiring Connections
UL NOTE
THE MINIMUM WIRE SIZE USED FOR TELEPHONE
INSTALLATIONS MUST BE #26 GAGE
WARNING
TO PREVENT
RISK OF SHOCK,
DISCONNECT
TELEPHONE LINE
AT TELECOM
JACK BEFORE
SERVICING
THIS UNIT
1000-100-004-V0
NOTE
USE ONLY THE
K10145WH/K10145X10
OR K10145CN
TRANSFORMER
PROVIDED
PREMISES
TELEPHONE
INCOMING
TELEPHONE
LINE
PIEZO
6-14VDC
120mA max.
6-14VDC
30mA max.
BELL
1
2
3
4
86
5
11
7
10
PHONE
ZONE
SOUNDERS
AC
EARTH
GROUND
9
K10145WH/K10145X10
OR K10145CN
PLUG-IN
TRANSFORMER
9VAC, 25VA
RING
TIP
RING
TIP
INCOMING
PHONE
LINE
8
POS
JACK
AC
AC
AC
AC
SOUND
OUT
HWZ
T
R
T
R
ALL OUTPUT CIRCUITS ARE POWER LIMITED.
HARD
WIRED
ZONE
2k
OHMS
EOLR
EARTH
GROUND
Note: For the complete Summary of Connections, refer to the Lynx Plus
Series Installation and Setup Guide P/N 800-03857 or higher
3. Make Battery Connections
1000-300-007-V0
BATTERY PACK
NOTE
WALYNXRCHKIT-SHA
BATTERY PACK SHOWN
RETAINER
SCREW
4. Program the Control
Change the Installer Code
The factory default Installer Code for the Lynx Plus Series Control is set
to 4-1-1-2. To change this code, you must enter Expert Programming
mode.
1. After Power-up, enter Installer Code + 8 0 0 or press both the []
and [#] simultaneously within 50 seconds after power is applied to
the control. The system will enter the Expert Programming Mode
and “20 INSTALLER CODE” will be displayed.
Note: Upon power-up or after exiting program mode, the system takes up
to a minute to reset. To bypass the reset delay, enter [#]+[0].
2. Enter 20
3. Enter a new four-digit Installer Code.
Program variable data fields
1. If required, enter 24 to program the desired 2-digit RF House ID
for wireless keypads.
2. If required, enter 40 to program a PABX Access Code or to
Disable Call Waiting (LynxSIA Plus only).
3. Enter 94 to program the downloading computer phone number.
4. Press the ESCAPE/ OFF key to enter Voice Prompt Program
mode. The system will announce, “Programming, use arrows
to scroll
choices, press select to accept, press escape to quit.” The system
will announce the available options.
1. Separate the front case from the rear case by rotating the front
case and releasing the hooks from the rear case.
2. Feed the wiring through the openings provided in the rear case.
3. Mount the rear case to a sturdy wall and secure with the provided
screws.
3. Reconnect the front case and rear case.
1. Make earth ground connections to terminal 1.
2. Connect the incoming phone line to either the 8-position jack or
terminals 2 (TIP) and 3 (RING).
3. Connect the handset phone lines to terminals 4 (TIP) and 5
(RING).
Note: For full line seize operation, refer to the Lynx Plus Series
Installation and Setup Guide.
4. If used, connect a piezo sounder or bell to terminals 8 (-) and 9
(+).
5. Connect the sensors/contacts to the hardwired zone terminals 6
(-) and 7 (+).
6. If used, connect the GSML or GSMVL communications device to
the GSML/GSMVL communications port.
7. Connect wires from the K10145WH/K10145 OR K10145CN
Transformer to terminals 10 and 11.
Note: If using Powerline Carrier Devices refer to the Lynx Plus Series
Installation Guide P/N 800-03857 or higher.
1. Remove screw securing the battery retainer.
2. Remove the battery retainer.
3. Insert battery pack into back plate.
4. Install battery retainer.
5. Install screw to secure the battery retainer.
6. Connect battery connector to receptacle on PC board.
7. After all wiring connections have been made, snap the front
assembly to the back plate so it is held by the locking tabs.
8. Plug the transformer into a 24-hour, 110VAC unswitched
outlet.
Note: Rechargeable batteries may take up to 48-hours to fully
charge. “LOW BAT” message should clear within four hours,
or by entering Test Mode.
5. Follow the directions provided by each voice prompt to make your
selections.
The FUNCTION/ # key can be used to repeat a voice prompt,
as required.
6. When you have completed each programming procedure the
system will return to the Main Programming Menu.
Viewing data fields
1. To view data entered in field, press [#] plus the field that you wish to view
(e.g., #21). The system will beep three times and data programmed for that
field will be displayed to the right of the field number. The system will scroll
through the data for longer numbers and a beep will sound after each
number is displayed or three times after the final digit is displayed.
(Continued on reverse side)