Lynx Plus
Lynx PlusLynx Plus
Lynx Plus Series
Series Series
Series Control
ControlControl
Control
Quick Installation Guide
This Quick Installation Guide can help you install the rechargeable Lynx Plus Series Control quickly and easily by providing the
basic steps for installation using the built-in defaults and the Voice Prompt Programming mode. The Voice Prompt
Programming mode allows you to quickly program the system by responding to a series of voice prompts.
FOR DOCUMENTATION AND ONLINE SUPPORT: http://www.security.honeywell.com/hsc/resources/MyWebTech
(see Lynx Plus Series Installation and Setup Guide P/N 800-03857 or higher)
WARRANTY INFORMATION
For the latest warranty information, please go to:
www.honeywell.com/security/hsc/resources/wa
1. Install the Control
1000-300-011-V0
FRONT
CASE
MOUNTING
HOOKS
LOCKING TABS
BACK
CASE
ROTATE
FRONT CASE
UPWARD
TO RELEASE
HOOKS
GSML/GSMVL
COMMUNICATIONS
PORT
GSMVL AUDIO
CABLE CONNECTOR
BATTERY
CONNECTIONS
PLCD
CONNECTOR
TELEPHONE
CONNECTION
2. Make Wiring Connections
UL NOTE
THE MINIMUM WIRE SIZE USED FOR TELEPHONE
INSTALLATIONS MUST BE #26 GAGE
WARNING
TO PREVENT
RISK OF SHOCK,
DISCONNECT
TELEPHONE LINE
AT TELECOM
JACK BEFORE
SERVICING
THIS UNIT
1000-100-004-V0
NOTE
USE ONLY THE
K10145WH/K10145X10
OR K10145CN
TRANSFORMER
PROVIDED
PREMISES
TELEPHONE
INCOMING
TELEPHONE
LINE
PIEZO
6-14VDC
120mA max.
6-14VDC
30mA max.
BELL
1
2
3
4
86
5
11
7
10
PHONE
ZONE
SOUNDERS
AC
EARTH
GROUND
9
K10145WH/K10145X10
OR K10145CN
PLUG-IN
TRANSFORMER
9VAC, 25VA
RING
TIP
RING
TIP
INCOMING
PHONE
LINE
8
POS
JACK
AC
AC
AC
AC
SOUND
OUT
HWZ
T
R
T
R
ALL OUTPUT CIRCUITS ARE POWER LIMITED.
HARD
WIRED
ZONE
2k
OHMS
EOLR
EARTH
GROUND
Note: For the complete Summary of Connections, refer to the Lynx Plus
Series Installation and Setup Guide P/N 800-03857 or higher
3. Make Battery Connections
1000-300-007-V0
BATTERY PACK
NOTE
WALYNXRCHKIT-SHA
BATTERY PACK SHOWN
RETAINER
SCREW
4. Program the Control
Change the Installer Code
The factory default Installer Code for the Lynx Plus Series Control is set
to 4-1-1-2. To change this code, you must enter Expert Programming
mode.
1. After Power-up, enter Installer Code + 8 0 0 or press both the [✼]
and [#] simultaneously within 50 seconds after power is applied to
the control. The system will enter the Expert Programming Mode
and “20 INSTALLER CODE” will be displayed.
Note: Upon power-up or after exiting program mode, the system takes up
to a minute to reset. To bypass the reset delay, enter [#]+[0].
2. Enter ✼20
3. Enter a new four-digit Installer Code.
Program variable data fields
1. If required, enter ✼24 to program the desired 2-digit RF House ID
for wireless keypads.
2. If required, enter ✼40 to program a PABX Access Code or to
Disable Call Waiting (LynxSIA Plus only).
3. Enter ✼94 to program the downloading computer phone number.
4. Press the ESCAPE/ OFF key to enter Voice Prompt Program
mode. The system will announce, “Programming, use arrows
to scroll
choices, press select to accept, press escape to quit.” The system
will announce the available options.
1. Separate the front case from the rear case by rotating the front
case and releasing the hooks from the rear case.
2. Feed the wiring through the openings provided in the rear case.
3. Mount the rear case to a sturdy wall and secure with the provided
screws.
3. Reconnect the front case and rear case.
1. Make earth ground connections to terminal 1.
2. Connect the incoming phone line to either the 8-position jack or
terminals 2 (TIP) and 3 (RING).
3. Connect the handset phone lines to terminals 4 (TIP) and 5
(RING).
Note: For full line seize operation, refer to the Lynx Plus Series
Installation and Setup Guide.
4. If used, connect a piezo sounder or bell to terminals 8 (-) and 9
(+).
5. Connect the sensors/contacts to the hardwired zone terminals 6
(-) and 7 (+).
6. If used, connect the GSML or GSMVL communications device to
the GSML/GSMVL communications port.
7. Connect wires from the K10145WH/K10145 OR K10145CN
Transformer to terminals 10 and 11.
Note: If using Powerline Carrier Devices refer to the Lynx Plus Series
Installation Guide P/N 800-03857 or higher.
1. Remove screw securing the battery retainer.
2. Remove the battery retainer.
3. Insert battery pack into back plate.
4. Install battery retainer.
5. Install screw to secure the battery retainer.
6. Connect battery connector to receptacle on PC board.
7. After all wiring connections have been made, snap the front
assembly to the back plate so it is held by the locking tabs.
8. Plug the transformer into a 24-hour, 110VAC unswitched
outlet.
Note: Rechargeable batteries may take up to 48-hours to fully
charge. “LOW BAT” message should clear within four hours,
or by entering Test Mode.
5. Follow the directions provided by each voice prompt to make your
selections.
The FUNCTION/ # key can be used to repeat a voice prompt,
as required.
6. When you have completed each programming procedure the
system will return to the Main Programming Menu.
Viewing data fields
1. To view data entered in field, press [#] plus the field that you wish to view
(e.g., #21). The system will beep three times and data programmed for that
field will be displayed to the right of the field number. The system will scroll
through the data for longer numbers and a beep will sound after each
number is displayed or three times after the final digit is displayed.
(Continued on reverse side)
Ê800-03860/Š
800-03860 9/09 Rev. A
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Copyright
© 2009 Honeywell International Inc.
www.honeywell.com/security